Milwaukee EC60 for quick EC, TDS and temperature checks of nutrient solutions
The Milwaukee EC60 EC/Temperature Meter is a compact digital handheld instrument for checking conductivity, TDS and temperature. With an EC range of up to 20.00 mS/cm, it is particularly suitable for nutrient solutions in indoor growing, hydroponic systems and other applications involving higher conductivity levels. The simultaneous temperature display lets you monitor important solution parameters with a single instrument.
EC value and temperature on one display
The dual-level display shows either EC or TDS together with the measured temperature. Its EC range extends from 0.00 to 20.00 mS/cm with a resolution of 0.01 mS/cm. Alternatively, TDS can be displayed up to 10.00 ppt. Temperature is measured from 0.0 to 60.0 °C with a resolution of 0.1 °C. You can find further instruments for nutrient solution monitoring in the range of EC meters for growing.
Automatic temperature compensation and calibration
Electrical conductivity changes with temperature, so the EC60 uses automatic temperature compensation to account for these variations. The temperature coefficient can be adjusted from 0.0 to 2.4%/°C. Calibration is automatic at one point, using a conductivity standard of 12.88 mS/cm or 12,880 µS/cm. The matching Milwaukee EC 12.88 buffer solution is suitable for regular calibration checks.
Designed for regular use
The housing is waterproof to IP65 and suited to damp working environments. Its Mi59P measuring probe is replaceable, so the complete meter does not need to be replaced when the probe eventually wears out. A stability indicator helps you identify a settled reading, while automatic shut-off after eight minutes of inactivity helps conserve battery power. Rinsing the probe with clean tap water after each measurement helps minimise nutrient deposits.
Technical details:
- Product type: digital EC, TDS and temperature meter
- Model: Milwaukee EC60
- EC range: 0.00–20.00 mS/cm
- EC resolution: 0.01 mS/cm
- EC accuracy: ±2% full scale
- TDS range: 0.00–10.00 ppt
- TDS resolution: 0.01 ppt
- TDS accuracy: ±2% full scale
- Temperature range: 0.0–60.0 °C
- Temperature resolution: 0.1 °C
- Temperature accuracy: ±0.5 °C
- Temperature compensation: automatic, β 0.0–2.4%/°C
- Calibration: automatic, 1 point
- Calibration value: 12.88 mS/cm or 12,880 µS/cm
- TDS conversion factor: selectable, default 0.5
- Probe: Mi59P, replaceable
- Protection rating: IP65
- Operating conditions: 0–50 °C, maximum 100% relative humidity
- Batteries: 4 × 1.5 V LR44/A76
- Battery life: approximately 100 operating hours
- Automatic shut-off: after 8 minutes of inactivity
- Included: Milwaukee EC60, protective cap, 20 ml 12.88 mS/cm calibration solution, batteries and instruction manual