Bluelab Guardian pH/EC Monitor WiFi

  • Continuous monitoring of nutrient solution pH, conductivity and temperature
  • Wi-Fi connection to Edenic for remote access, measurement history and smartphone notifications
  • Adjustable high and low alarm limits for all three parameters
  • Large green LED displays with adjustable brightness settings
  • Replaceable pH probe with BNC connector, both probes with 2 m cables
449,90 €
incl. 19% VAT , plus shipping costs
Piece
  • Available immediately
  • Delivery time: 2 - 5 Workdays (DE - int. shipments may differ)


Description

Bluelab Guardian pH/EC Monitor WiFi – keep track of your reservoir, wherever you are

The Bluelab Guardian pH/EC Monitor WiFi continuously measures the pH, electrical conductivity and temperature of your nutrient solution. This mains-powered monitor suits beginners and experienced growers who need to track reservoir conditions between manual checks. Read all three values directly on the unit or follow them remotely through Edenic.

Clear readings and adjustable alarm limits

Three large green LED displays show your readings simultaneously, with brightness that can be adjusted to suit the location. Set upper and lower alarm limits for pH, conductivity and temperature. When a reading moves outside its set range, the display flashes to highlight the change. Your settings are retained if the power supply is interrupted.

Remote monitoring through Wi-Fi and Edenic

Connect the monitor to your Edenic account using a 2.4 GHz Wi-Fi network to access current readings, review measurement history and receive alarm notifications on your smartphone. Bluetooth assists with initial setup. Remote access and online data logging require an internet connection, but no Connect Stick or continuously running computer is needed. Wi-Fi can be disabled when not required.

When planning your system, bear in mind that the Guardian is a monitoring device. It does not automatically dose nutrients or pH adjusters.

Reservoir installation and a replaceable pH probe

Mount the monitor on a wall or hang it from a suitable support near your reservoir. Protect the display unit from water. Both probes must sit in the same nutrient solution for automatic temperature compensation of the pH reading to work. The pH probe uses a BNC connector, so a compatible Bluelab replacement pH probe lets you replace the sensor rather than the entire monitor.

Calibration and probe care

Calibrate the pH probe before first use and at least monthly afterwards, using pH 7.0 followed by either pH 4.0 or pH 10.0. The Bluelab pH Cleaning and Calibration Set provides suitable supplies for cleaning and calibration. Conductivity and temperature require no user calibration, although both probes still need regular cleaning.

Never allow the pH probe tip to dry out. When it is not in use, keep the tip moist with KCl storage solution in its protective cap. Do not use distilled or reverse osmosis water for storage.

Technical details:

  • Product type: Continuous Wi-Fi monitor for nutrient solutions
  • Model: Bluelab Guardian Monitor Wi-Fi, BGUSTD02
  • pH measurement range: 0.0–14.0 pH
  • EC measurement range: 0.0–5.0 mS/cm
  • CF measurement range: 0–50 CF
  • TDS measurement range, 500 scale: 0–2500 ppm
  • ppm measurement range, 700 scale: 0–3500 ppm
  • Temperature measurement range: 0–50 °C or 32–122 °F
  • pH resolution: 0.1 pH
  • EC resolution: 0.1 mS/cm
  • Temperature resolution: 1 °C or 1 °F
  • pH accuracy at 25 °C: ±0.1 pH
  • EC accuracy at 25 °C: ±0.1 mS/cm
  • Temperature accuracy at 25 °C: ±1 °C or ±2 °F
  • Temperature compensation: Automatic for pH and conductivity; pH compensation requires both probes in the same solution
  • pH calibration: Two-point calibration using pH 7.0 and either pH 4.0 or pH 10.0
  • Connectivity: 2.4 GHz Wi-Fi, Bluetooth for setup
  • Probe cables: 2 m each
  • pH probe connection: BNC, replaceable probe
  • Power supply: Power adapter with 100–240 V AC input, 50–60 Hz
  • Operating temperature: 0–50 °C
  • Included: 1 Guardian Monitor Wi-Fi with conductivity/temperature probe, 1 pH probe, 1 pH probe holder with suction cup, 1 power supply with 4 plug adapters for Europe, the UK, North America and Australia/New Zealand, 4 mounting screws, 2 cable ties, plus 1 sachet each of pH 7.0 calibration solution, pH 4.0 calibration solution and KCl storage solution, containing 18 ml each

EC-Wert Umrechnung in PPM

Product safety information
Manufacturer information:
Bluelab
Whiore Avenue 8
Tauranga, Neuseeland, 3171
[email protected]
https://bluelab.com/emea/ticket-to-support
Responsible person:
Binnen Tuinbouw Techniek (BTT)
Goudstraat 65